Abstract

OBJECTIVE


To compare the diagnostic accuracy of SIARI and LRINEC score for early detection of necrotizing fasciitis


METHODOLOGY


This cross-sectional study was conducted at the department General Surgery Civil Hospital Karachi from October 2024 to March 2025. Non-Probability consecutive sampling was used to recruit the 73 patients aged 18 years and above of both gender and with suspected severe soft-tissue infection. The inclusion criteria consist of clinical suspicion should be NF. LRINEC scores were compared to SIARI scores. The measurements of diagnostic accuracy were done through ROC analysis where p ≤ 0.05 was taken as significant.


RESULTS


Among 73 patients (mean age 45.78±17.39 years; 74% were males), the SIARI score demonstrated higher diagnostic accuracy, with a higher AUC (0.824; p = 0.0001), greater sensitivity (96.6%), and higher diagnostic accuracy (82.2%), whereas the LRINEC score showed comparatively lower discriminative ability (AUC = 0.665; p = 0.018).


CONCLUSION


The present findings revealed that the SIARI score was found to be more accurate in diagnosis of NF at an early stage than the LRINEC score. SIARI was more discriminative and sensitive in recognizing confirmed cases whereas LRINEC had lower diagnostic performance. These results revealed discrepancies in the effectiveness of the two scoring systems in separating NF and other serious soft-tissue infections.

Downloads

Download data is not yet available.

Article Details

Section

Articles

How to Cite

SIARI VS LRINEC: ACCURATE TOOL FOR DIAGNOSIS OF NECROTIZING FASCIITIS. (2025). The Research of Medical Science Review, 3(6), 1605-1611. https://medicalsciencereview.com/index.php/Journal/article/view/3040