DIAGNOSTIC ACCURACY OF X-RAY KUB ((KIDNEY, URETER, BLADDER) IN DETECTING URETEROLITHIASIS USING CT SCAN AS GOLD STANDARD

Main Article Content

Dr. Rukhsar Butt
Dr. Tahir malik
Dr. Sahar Zulfiqar
Dr Fatima sehar
Dr. Momin Mazhar
Dr Kanwal Shan

Abstract

Objective


To determine   diagnostic accuracy of X-ray KUB in detecting ureterolithiasis using CT scan as   gold standard.


Methods:


Cross-sectional validation study was conducted at Pakistan Kidney and Liver Institute and Research Centre; data collection was done between March to June, 2025.   total of 362 patients aged 20–60 years with clinical suspicion of ureteric colic were included. All patients underwent X-ray KUB followed by NCCT KUB. Diagnostic indices were calculated using   2×2 contingency table.


Results:


Out of 362 patients, CT scan confirmed ureterolithiasis in 148 (40.9%). X-ray KUB showed sensitivity of 64.2%, specificity of 81.3%, positive predictive value of 72.1%, negative predictive value of 75.8%, and overall diagnostic accuracy of 74.0%.


Conclusion:


X-ray KUB demonstrates moderate diagnostic accuracy and may be used as   initial screening tool in suspected ureterolithiasis, particularly in resource-limited settings, but cannot replace CT scan for definitive diagnosis.